| Vacuum  Relief Valves
 Pressure  relief valves are used to maintain near atmospheric or low vacuum conditions within a vessel whilst minimising exposure to atmosphere.       
         Vacuum and Tank Equipment  Combined Valve and Flame Arrester Combination Catalogue
 
  Model 13S-TOW Groth Vacuum Relief Valve (VRV) - Weight Loaded, Horizontal Mounted
 
 The new Groth Model 13S-T0W-0 is used when vacuum relief is the only requirement. The13S-T0W-0 is side mounted on the tank body or piped in. Intake relief necessary under
 working conditions is achieved by a weight loaded pallet. This feature reduces the possibility
 of tank damage due to an excessive vacuum condition. Valve size must be selected to
 perform required vacuum relief under operating and thermal conditions.
 
        
          
            
              
                
                  
                     10% Overpressure Advantage - Full rated flow capacity achieved at 10% over-pressure Product leakage and fugitive emissions are reduced via ultra-tight sealingHigher flow capacity to protect from excessive vacuum build upPeripheral and central seat guides ensure reliable, repeatable performanceDesigned for easy maintenance, thus reducing downtime and operational costCompliant to API-2000 and ISO 28300 standards 
                     Data Sheet
 
  Model 13T-TOW Groth Vacuum Relief Valve (VRV) - Weight Loaded, Top Mounted
 
 The Groth Model 13T-T0W-0 weight loaded vacuum relief valve is designed to beused in applications where additional vacuum relief is necessary. Intake relief necessary
 under working conditions is achieved by a weight loaded pallet. The 13T-T0W-0
 helps to provide increased fire protection and safety. Valve size must be selected to
 perform required vacuum relief under operating and thermal conditions.
 
        
          
            
              
                
                  
                     10% Overpressure Advantage - Full rated flow capacity achieved at 10% over-pressure Product leakage and fugitive emissions are reduced via ultra-tight sealingHigher flow capacity to protect from excessive vacuum build upPeripheral and central seat guides ensure reliable, repeatable performanceDesigned for easy maintenance, thus reducing downtime and operational costCompliant to API-2000 and ISO 28300 standards 
                     Data Sheet
 
  Model 1300A Groth Vacuum Relief Valve
 
 The Groth Series 1300A is used when vacuum relief is the only requirement. Intake relief necessary under working conditions is achieved by a spring or weight loaded pallet. This feature reduces the possibility of tank damage due to an excessive vacuum condition. The 1300A Series helps to provide increased fire protection and safety. Valve size must be selected to perform required vacuum relief under operating and thermal conditions. 
        
          
            
              
                
                  
                            Modular Construction Cushioned air seating Fluoropolymer seating diaphragms minimize sticking caused by resinous vapors and atmospheric moisture Self-draining housing body and drip rings to protect seating surfaces from condensate and freezing Design avoids vacuum buildup due to binding or clogging of the ventCompliant to API-2000 and ISO 28300 standards 
                     Data Sheet
 
  Model 1360A Groth Pressure Relief Valve      - Side Mount
 
 The Groth Model 1360A Vacuum Relief Valve is used when vacuum relief is the only requirement. The 1360A may be side mounted on the tank body or piped in. Intake relief necessary under working conditions is achieved by a spring or weight loaded pallet. The 1360A helps to provide increased fire protection and safety. Valve size must be selected to perform required vacuum relief under operating and thermal conditions.       
      
        
          
            
              
                
                  Modular ConstructionCushioned air seatingFluoropolymer seating diaphragms minimize sticking caused by resinous vapors and atmospheric moisture Self-draining housing body and drip rings to protect seating surfaces from condensate and freezing Design avoids vacuum buildup due to binding or clogging of the ventCompliant to API-2000 and ISO 28300 standards  
                   Data Sheet
 
  Model 1361A Groth Pressure Relief Valve
 
 The Groth Models 1361A are used when vacuum relief is the only requirement.Intake relief necessary under working conditions is achieved by a spring or weight loaded
 pallet. This feature reduces the possibility of tank damage due to an excessive vacuum
 condition. Valve size must be selected to perform required vacuum relief under operating and
 thermal conditions.
 
      
        
          
            
              
                
                          Modular ConstructionCushioned air seatingFluoropolymer seating diaphragms minimize sticking caused by resinous vapors and atmospheric moistureSelf-draining housing body and drip rings to protect seating surfaces from condensate and freezing Design avoids vacuum buildup due to binding or clogging of the ventCompliant to API-2000 and ISO 28300 standards 
                   Data Sheet
     |